Online DCA-10 Manual
Menu

Specifications

 
Technical Data DCA - 10
 
Mechanical Construction
 
 
 
Material
Body - Polycarbonate
Cover - Brushed Aluminium
Overall Weight
250 grammes
Dimensions
Refer to drawing - General Arrangement Drawing
Mounting
TS35 DIN Rail
 
 
Environmental Conditions
 
 
 
Operating temperature range
5-50 degrees Celsius
 
 
Electrical Characteristics
 
 
 
Electrical connections
Screw type terminals 2,5 mm²
Supply voltage     :
24 V DC 10% / ripple  5%
Maximum supply voltage
30V DC
Consumption
max. 2,5 W
Strain Gauges
350 Ohm, Full Wheatstone Bridge Only
Voltage for bridge supply [Excitation]
Stabilised 10V DC 40mA Typical
Zero adjustment (TARE)
Automatic
Zero Adjustment possible offset range
12,5 mV is equal to max. 50 % of sensor signal at 25mV end range
Adjustment for amplification
automatic
Possible input range
2 mV to 25 mV
Overload capability of inputs
0 ... +/- 50 mV
Signal outputs
Channel A
Channel B
Channel A+B
3 Channels 0 to +10 Volts DC
 
Input resistance
1 M Ohm
Range switching
25%,50%,75%,100%
by switching inputs 9,10 and 12,13
Max. frequency
5kHz
Monitor outputs
Channel A
Channel B
Channel A+B
0...+10 V / max. 5 mA
Max. frequency
0,3 Hz
Linearity error
0,005%
Temperature drift
0,002%/K
Zero point error
+/- 5 mV
Amplification error
+/- 5 mV
Recommended transducer connecting cable
4 core and screen 16-2-4C DEF STAN 61-12
RS485 serial link
9600 Baud, 8 Data bits, 1 Stop bit, No Parity